General Specifications CommScope R-144-LN-8W-F12BK/25D TeraSPEED
- Construction Type Non-armored
- Cable Type Stranded loose tube
- Subunit Type Gel-free
Construction Materials CommScope R-144-LN-8W-F12BK/25D TeraSPEED
- Fiber Type Solution G.652.D and G.657.A1 , TeraSPEED® | OS2
- Total Fiber Count 144
- Fiber Type G.652.D and G.657.A1, TeraSPEED® | OS2
- Fiber Type, quantity 144
- Fibers per Subunit, quantity 12
- Jacket Color Black
- Jacket UV Resistance UV stabilized
Dimensions
- Buffer Tube/Subunit Diameter 2.50 mm | 0.10 in
- Cable Weight 264.0 kg/km | 178.0 lb/kft
- Diameter Over Jacket 17.10 mm | 0.67 in
- Subunit, Quantity 12
Physical Specifications CommScope R-144-LN-8W-F12BK/25D TeraSPEED
- Minimum Bend Radius, loaded 25.7 cm | 10.1 in
- Minimum Bend Radius, unloaded 17.1 cm | 6.7 in
- Tensile Load, long term, maximum 800 N | 180 lbf
- Tensile Load, short term, maximum 2700 N | 607 lbf
- Vertical Rise, maximum 309.0 m | 1013.8 ft
Flame Test Specifications
- Flame Test Listing NEC OFNR (ETL) and c(ETL)
- Flame Test Method UL 1666
Environmental Specifications
- Environmental Space Riser
- Installation Temperature -30 °C to +70 °C (-22 °F to +158 °F)
- Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
- Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications CommScope R-144-LN-8W-F12BK/25D TeraSPEED
- Compression 22 N/mm | 125 lb/in
- Compression Test Method FOTP-41 | IEC 60794-1 E3
- Flex 35 cycles
- Flex Test Method FOTP-104 | IEC 60794-1 E6
- Impact 5.88 N-m | 4.34 ft lb
- Impact Test Method FOTP-25 | IEC 60794-1 E4
- Strain See long and short term tensile loads
- Strain Test Method FOTP-33 | IEC 60794-1 E1
- Twist 10 cycles
- Twist Test Method FOTP-85 | IEC 60794-1 E7
- Water Penetration 24 h
- Water Penetration Test Method FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
- Cable Freeze -2 °C | 28 °F
- Cable Freeze Test Method FOTP-98 | IEC 60794-1 F15
- Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
- Heat Age Test Method IEC 60794-1 F9
- Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
- Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
- Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
- Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1